The AX5806 TwinSAFE component is an option card for the AX5000 servo drive series from 60 A to 170 A and enables the implementation of safety-relevant drive functions. These functions are controlled via FSoE by a TwinSAFE Logic-capable component.
Drive-integrated safety functions:
- stop functions (STO, SOS, SS1, SS2)
- speed functions (SLS, SSM, SSR, SMS) with up to 8 speeds
- position functions (SLP, SCA, SLI) with reference cams
- acceleration functions (SAR, SMA)
- rotating direction functions (SDIp, SDIn)
Suitable for AX5000 Servo Drives from 60 A to 170 A:
- AX5160-0000-0200 and -0202
- AX5172-0000-0200 and -0202
- AX5190-0000-0200 and -0202
- AX5191-0000-0200 and -0202
- AX5192-0000-0200 and -0202
- AX5193-0000-0200 and -0202
Product status:
regular delivery
Product information
| Technical data | AX5806 |
|---|---|
| Function | TwinSAFE option card |
| Drive profile | FSoE |
| Safe acceleration functions | Safe Maximum Acceleration (SMA), Safe Acceleration Range (SAR) |
| Safe direction functions | Safe Direction positive (SDIp), Safe Direction negative (SDIn) |
| Safe speed functions | Safe Speed Range (SSR), Safely Limited Speed (SLS), Safe Speed Monitor (SSM), Safe Maximum Speed (SMS) |
| Safe position functions | Safely Limited Position (SLP), Safe CAM (SCA), Safely Limited Increment (SLI) |
| Safe stop functions | Safe Torque Off (STO), Safe Stop 1 (SS1), Safe Stop 2 (SS2), Safe Operating Stop (SOS) |
| Safety standard | EN ISO 13849-1:2015 (Cat. 4, PL e) and IEC 61508:2010 (SIL 3) |
| Realization STO | via FSoE |
| Approvals/markings | CE, cULus |
| Ambient temperature (operation) | 0…50°C |